Test Engineer:Simon Mo
 
Report No.:  RSZ 07112202
 
Test Date:  2007-12-19 to 2007-12-20
 
Reviewed By:EMC Manager: Green Xu
 
Prepared By:
Bay Area Compliance Laboratories Corp. (Shenzhen)
6/F, the 3rd Phase of WanLi Industrial Building, 
ShiHua Road, FuTian Free Trade Zone
Shenzhen, Guangdong, China
Tel: +86-755-33320018
Fax: +86-755-33320008
 
Product Description for Equipment under Test (EUT)
 
The Vson Technology Co., Ltd. 's product, model: V-850 or the "EUT" as referred to in this report is a
Integrative Mini Presenter which measures approximately 13.7 cm L x 3.3 cm W x 0.7 cm H, rated input
voltage: DC 3V battery.
* All measurement and test data in this report was gathered from production sample serial number:
0711032 (Assigned by BACL, Shenzhen). The EUT was received on 2007-11-22.
 
Objective
 
This document is a test report based on the Electromagnetic Interference (EMI) tests performed on the
EUT. The EMI measurements were performed according to the measurement procedure described in
ANSI C63.4 - 2003.
The tests were performed in order to determine compliance with FCC Part 15, Subpart C, and section
15.203, 15.205, 15.209 and 15.231 rules.
Related Submittal(s)/Grant(s)
No Related Submittals
Test Methodology
All measurements contained in this report were conducted with ANSI C63.4 - 2003, American National
Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and
Electronic Equipment in the range of 9 kHz to 40 GHz. All radiated and conducted emissions
measurement was performed at Bay Area Compliance Laboratories Corp. (Shenzhen). The radiated testing
was performed at an antenna-to-EUT distance of 3 meters.
 
Test Facility
 
The Test site used by Bay Area Compliance Laboratories Corp. (Shenzhen) to collect test data is located in
the 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen,
Guangdong, China.
Test site at Bay Area Compliance Laboratories Corp. (Shenzhen) has been fully described in reports
submitted to the Federal Communication Commission (FCC). The details of these reports have been
found to be in compliance with the requirements of Section 2.948 of the FCC Rules on November 04,
2004. The facility also complies with the radiated and AC line conducted test site criteria set forth in
ANSI C63.4-2003.
The Federal Communications Commission has the reports on file and is listed under FCC Registration No.:
382179. The test site has been approved by the FCC for public use and is listed in the FCC Public Access
Link (PAL) database.
Additionally, Bay Area Compliance Laboratories Corp. (Shenzhen) is a National Institute of Standards and
Technology (NIST) accredited laboratory, under the National Voluntary Laboratory Accredited Program
(Lab Code 200707-0).
 
The current scope of accreditations can be found at
http://ts.nist.gov/Standards/scopes/2007070.htm